proportioner, metering unit,
sprayer, dispenser, foam machine, coating machine, plural-component,
polyurethane, polyurea, gusmer, graco, spray foam, foam insulation, fiberglass,
cellulose, h20, h25, h20/35, hv20, h-2000, h-3500, h35, mmh, glas-craft,
glacraft, glascraft, gsmer, gusmr, foam, insualtion, poyuretane, polyretane,
polyurethane, polyurethane, schaum, ausschauemen, spritzschaum, spritzen, cheap
foam, meter unit, 2-component, transfer pump, husky, ipm, allegro, icynene,
low-density foam, hydraulic, reactor, super-maxi, foamer, foam roofer, hydralic,
hydrolic, demilec, hxp2, xp2, h-xp2, electric, reactor, reactor
Dependable Hydraulics with
Maximum Control
|
|

Graco Fusion gun
Click on the photo to see a larger
image!
Key Applications
- Tank and pipe coating
- Wastewater treatment
- Railcar manufacturing
- Insulation
- Roof coating and insulation
Key Materials
- Polyurea coatings
- Foam
- Polyurethane coatings
Literature
Manuals
|

Graco H25
/ H-XP2
Click on photo to see a larger image! |
|
The first
hybrid
Graco|Gusmer unit on
the market - get the best
of both technologies! |
-
Performance-driven, horizontal pump system
-
Entry-level hydraulic foam and polyurea units
-
System controls with diagnostics and auto
shutdown
-
Durable hydraulics
-
SoftStart ™ feature with 1/3 less power draw during
startup
User defined pressure imbalance
shut-off offers more
control
System controls with advanced diagnostics and auto
shutdown
User defined standby mode reduces wear on
hydraulic pump
Reduced weight and footprint
Graco H25 / H-XP2
Click on the photo to see a larger image!
H-25 Proportioner - up to 20 lbs./min
-
-
Pump line consistent with Gusmer 120 series
offering
•
-
Product choices
–-
8 kW or 15.3 kW heater
–-
210’ or 310’ maximum hose length transformers
–-
Voltages and phases
• -
230 V, single phase
• -
230 V, three phase
• -
380 V, three phase
H-XP2 Proportioner - up to 1.5 gal/min.
-
-
Pump line consistent with Gusmer 80 series
offering
•
-
Product choices
–-
15.3 kW heater standard (no other choice)
–-
210’ or 310’ maximum hose length transformers
–-
Voltages and phases
• -
230 V, single phase
• -
230 V, three phase
• -
380 V, three phase
|
- The chart on the right shows how each of the
selected Graco systems maintains pressure using various mixing
chamber sizes.
- The interesting fact is that the H-25 maintains
about 1800 psi even when spraying at a rate of 24 lbs. per minute.
- When spraying larger jobs, the H-25 keep
production up at a much higher rate than the
E-20!
|
 |
- Peak power at startup is reduced by about
65%. This makes it easy for the generator or other power
supply.
- Graph shown is based on average recorded amperage during
startup.
- Average draw reduced from 107 amps to 62
amps
- Motor phase is changeable with harness kit.
No motor change required for phase change!
|
 |
|
Please refer to the following table to determine
your desired configuration. To find out about the current pricing,
please click on the item number, and you will be taken to CPI's online
line store where the current price will be displayed from our database.
|
Special Pricing Possible!
We have almost
always demo machines for sale. Typically, these system only have been
used for
a few weeks in our training center, and then they are sold! Please call if you
are
interested!
Demos Available!
Please call to schedule
your personal demo at our training center! |
| As you can see in the table, the machines are
available in different configurations. Beside the obvious choice of
voltage and phase, there is also a choice of different maximum
pressures, primary heater packages and two different transformers for
the hose heat. |
|
Foam Systems |
|
Item ID |
Voltage |
Phase |
Heater |
Amps |
Max. Pressure |
Transformer |
|
253200 |
230 V |
1 PH |
8.0 kW |
63 |
2000 psi/140 bar |
210' |
|
253201 |
230 V |
3 PH |
8.0 kW |
40 |
2000 psi/140 bar |
210' |
|
253202 |
380 V |
3 PH |
8.0 kW |
29 |
2000 psi/140 bar |
210' |
|
|
|
|
|
|
|
|
|
253206 |
230 V |
1 PH |
15.3 kW |
95 |
2000 psi/140 bar |
210' |
|
253207 |
230 V |
3 PH |
15.3 kW |
58 |
2000 psi/140 bar |
210' |
|
253208 |
380 V |
3 PH |
15.3 kW |
35 |
2000 psi/140 bar |
210' |
|
|
|
|
|
|
|
|
|
253300 |
230 V |
1 PH |
8.0 kW |
69 |
2000 psi/140 bar |
310' |
|
253301 |
230 V |
3 PH |
8.0 kW |
45 |
2000 psi/140 bar |
310' |
|
253302 |
380 V |
3 PH |
8.0 kW |
35 |
2000 psi/140 bar |
310' |
|
|
|
|
|
|
|
|
|
253306 |
230 V |
1 PH |
15.3 kW |
100 |
2000 psi/140 bar |
310' |
|
253307 |
230 V |
3 PH |
15.3 kW |
58 |
2000 psi/140 bar |
310' |
|
253308 |
380 V |
3 PH |
15.3 kW |
35 |
2000 psi/140 bar |
310' |
|
Coating (Polyurea) Systems |
|
253203 |
230 V |
1 PH |
15.3 kW |
95 |
3500 psi/240 bar |
210' |
|
253204 |
230 V |
3 PH |
15.3 kW |
58 |
3500 psi/240 bar |
210' |
|
253205 |
380 V |
3 PH |
15.3 kW |
35 |
3500 psi/240 bar |
210' |
|
|
|
|
|
|
|
|
|
253303 |
230 V |
1 PH |
15.3 kW |
100 |
3500 psi/240 bar |
310' |
|
253304 |
230 V |
3 PH |
15.3 kW |
58 |
3500 psi/240 bar |
310' |
|
253305 |
380 V |
3 PH |
15.3 kW |
35 |
3500 psi/240 bar |
310' |
|
|