Canadian Construction
Materials Centre (CCMC)
# 13243-R
Density (ASTM D-1622)
0.51 lbs/ft3
6.83 kg/m3
Thermal Resistance (ASTM C 518)
R 3.75 ft2 F/BTU
RSI 0.66 m2 C/W
Water Vapour Permeance (ASTM E96)
1861 ng/(Pa•s•m2) @ 50mm thickness
Water Absorption (ASTM D2842)
18%
Burn Characteristics
Flame Spread: 454 (ULC S-127 Corner Wall)
Smoke Development: 350 (ULC S-102 Steiner Tunnel)
Dimensional Stability (ASTM D-2126)
80º C @ AMB RH: -9.1%
70º C @ 97% RH: -11.9%
-29º C @ AMB RH: 0.9%
Acoustic Properties (STC)
30 @ 3½" depth 36 @ 5½" depth
| Noise Attenuation by
Frequency |
| Hz |
dB @3½" |
dB @5½" |
| 80 |
-18 |
-19 |
| 160 |
-17 |
-18 |
| 315 |
-30 |
-33 |
| 500 |
-32 |
-35 |
| 800 |
-36 |
-39 |
| 1250 |
-40 |
-38 |
| 2000 |
-41 |
-41 |
| 3150 |
-43 |
-42 |
| 5000 |
-47 |
-46 |
Open-Cell Count (ASTM D-2856)
98% (standards require greater than 90%).
Tensile Strength (ASTM D-1623)
Greater than 3. Passed.
Electrical Wiring
Home Foam can be used with 14/3 and 12/2 wiring (122º F / 50º C)
without affecting wire coverings. |
Corrosion
Home Foam does not cause corrosion to steel.
Bacteria and Fungi
Home Foam is not a food source for mould. With it's unique air
barrier qualities, it does not allow airborne transmission of
moisture, food, or spores into the envelope of a structure.
Rodents and Pests
Home Foam is not a food source for insects, rodents, or other
pests.
Environmental Health and Safety
Home Foam contains no formaldehyde, CFC of HCFC. It is 100%
water blown. Home Foam has been tested for VOCs by SRC and, as a
result of its exceptional performance, a mere 24-hour occupancy
waiting period was recommended for extremely sensitive
individuals.
Caution
Home Foam should not be installed within 2" / 50mm of heat
emitting devices producing temperatures in excess of 200º F /
93º C.
Packaging and Storage
Home Foam is supplied in 55 US gallon steel drums. Component A,
isocynate, is shipped in red drums and must be protected from
moisture and freezing. Component B, resin, is shipped in white
drums and must be protected from temperatures above
120º F / 49º C.
Application Requirements
For optimum yield, Home Foam should be sprayed at 600-1000psi at
120-130º F / 49-54º C. Component B should be stirred/mixed well
both before and during application.
When applied by trained and certified
installers, Home Foam yields have reached 24,000 bd ft / 5663 bd
m of consistently perfect foam per material set.
Warranty
Home Insulation Corporation warrants that, when applied by
certified installers following the product installation
instructions, all properties of Home Foam will be consistent
with the specifications detailed on this page.
The physical and performance
properties of Home Foam/Insulthane 100 were determined by tests
conducted by ULC and Warnock-Hersey. Specifications may be
revised periodically as the quest to improve Home Foam
continues. Please ensure you are referring to current
specifications. |